SeaVint

6.1.6 MARPOL Annex VI NOx Compliance and Record Keeping

Rotational 1ChemicalLNGLPGOilAsked to: Master, Chief Engineer, Engineer officersWhere: Chief Engineer's Office, Documentation, Engine Control Room

Are the documents and records needed to show compliance with MARPOL Annex VI Regulation 13 on NOx emissions complete and correct, including those for any NOx abatement equipment fitted?

In one lineEach engine has its EIAPP certificate, Technical File and parameter records up to date, and Tier III operation and failures are recorded and reported.

How to answer

  • Explain which engines are covered, their Tier, and where the EIAPP certificates and Technical Files are kept
  • Explain how the Record Book of Engine Parameters is updated when parts such as injectors, nozzles or turbocharger components are replaced
  • Where SCR or EGR is fitted, describe in simple terms how it works, the reductant (urea) system, and the checks you make before entering a NOx ECA
  • Explain what you do if the abatement system fails and cannot be fixed quickly: inform the Master and the company, record the failure, report to the flag and to the port State as required, and follow the company and flag guidance
  • Explain how catalyst condition is monitored according to the maker's instructions, for example NOx readings, pressure drop across the reactor, and inspection or sample results

What the inspector looks for

  • An EIAPP certificate, NOx Technical File and Record Book of Engine Parameters for each diesel engine over 130 kW
  • Engine components and settings that agree with the Technical File, with any replacements recorded
  • Tier changeover records with date, time and position when entering or leaving a NOx Emission Control Area, where Tier III applies
  • SCR or EGR operating records, reductant consumption and alarm or failure records
  • Engineers who understand the abatement system and the actions to take if it fails

Have ready to show

  • EIAPP certificates and NOx Technical Files
  • Record Book of Engine Parameters
  • IAPP Certificate and Supplement
  • Tier changeover log entries for NOx ECAs
  • SCR or EGR operating manual, monitoring records and reductant consumption records
  • The company procedure for NOx abatement failure

Avoid

  • Missing EIAPP certificates or Technical Files
  • Component replacements not recorded in the parameter record book
  • Missing Tier III changeover records in a NOx ECA
  • Engineers unable to explain the actions on failure of the SCR or EGR

Practise in the interview trainer All questions

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.