SeaVint

6.2.1 Flooding or accidental leakage of cargo pumproom bilges

Rotational 2ChemicalOilAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Cargo Control Room, PumproomOnly if it applies to the ship

On tankers with a cargo pumproom, do the Master and officers know how to pump out the pumproom bilges after flooding or a cargo leak, and is that equipment in working order?

In one linePumproom bilges can be pumped to the slop tank using remote-operated controls from outside the space, and the bilge alarms are tested and recorded.

How to answer

  • Explain how bilges are pumped out with the stripping pump, eductor or dedicated bilge pump into the slop tank, and how the line-up is made
  • Point out the remote controls for the bilge pump and the suction and discharge valves, on deck or in the CCR, so the system can be used without entering a flooded or gas-filled pumproom
  • Explain the pumproom bilge high level alarm, where it sounds, and how and how often you test it
  • Explain that if the pumproom floods with cargo you treat it as an emergency: raise the alarm, stop cargo operations, ventilate and gas test before entry, and follow the emergency plan
  • Explain that pumproom bilge contents are recorded in the ORB Part II when transferred to the slop tank

What the inspector looks for

  • A working bilge pump or eductor and suction valves that can be operated from outside the pumproom
  • Pumproom bilge high level alarms tested and recorded
  • Bilges clean and dry, and suction strainers clear
  • Officers who can describe how the bilges are drained to the slop tank, never overboard
  • Records of the bilge system in the PMS

Have ready to show

  • Pumproom bilge system drawing and the remote operating positions
  • Bilge alarm test records
  • PMS records for the bilge pump or eductor and the valves
  • Pumproom entry checklist and gas detection records
  • ORB Part II entries for bilge transfers

Avoid

  • Remote valve operators that are seized, unmarked or not working
  • Oil or cargo residue left in the bilges
  • Untested or isolated bilge alarms
  • Officers who can only describe draining the bilges from inside the pumproom

Practise in the interview trainer All questions

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.