6.5.2 Incinerator operation

Rotational 1ChemicalLNGLPGOilAsked to: Chief Engineer, Engineer officersWhere: Engine Room, Interview - Engineer Officer

Do the engineers know the company procedure for operating the incinerator safely, and is the incinerator in good order and used in line with the procedure and MARPOL?

In one lineTrained engineers only, interlocks working, no prohibited items such as batteries or PVC, no burning in port, every burn and ash logged.

How to answer

  • Explain who may operate the incinerator according to the company procedure, and what supervision and training they need
  • Describe start-up: preheat to the required combustion temperature, then load in batches or burn sludge, and monitor temperature and flame
  • Explain the interlocks, for example that the charging door cannot be opened while the burner is firing or the chamber temperature is high, and the flame failure and over-temperature trips
  • List the prohibited items: cargo residues and contaminated packing, PCBs, PVC (unless the incinerator is approved for it), garbage with more than traces of heavy metals, and batteries and aerosols because they can explode
  • Explain that you do not incinerate in ports or where local rules prohibit it, and that ash is landed ashore and recorded as category E

What the inspector looks for

  • An IMO type-approval certificate for the incinerator, where required
  • Operation only by trained and authorised persons, supervised as the procedure requires
  • Safety interlocks working: no charging door opening during burning, flame failure, temperature trips
  • Knowledge of the items that must not be incinerated, and of port or coastal restrictions
  • Records in the Garbage Record Book and ORB Part I for sludge burning; ash landed ashore

Have ready to show

  • Incinerator type approval certificate and maker's manual
  • Incinerator operating log
  • Garbage Record Book and ORB Part I entries
  • Interlock test records in the PMS
  • Incinerator operating instructions posted at the unit

Avoid

  • Interlocks bypassed, or the charging door able to open during operation
  • Batteries, aerosols or plastics found in the incinerator area
  • Incineration recorded while in port
  • Untrained crew operating the incinerator alone

Practise in the interview trainer All questions