6.6.1 Oil filtering equipment
Rotational 1ChemicalLNGLPGOilAsked to: Master, Chief Engineer, Engineer officersWhere: Engine Control Room, Engine Room, Interview - Engineer Officer
Do the Master and engineers know the company procedures for using the bilge oily water separator and 15 ppm alarm, and is the equipment in good condition and operated in line with the procedures, maker's manual and MARPOL Annex I?
In one lineCalibrated 15 ppm alarm and three-way valve tested; overboard valve and flanges sealed; any defect or tampering stopped, recorded, reported.
How to answer
- Describe the test of the 15 ppm alarm together with the three-way valve or automatic stop: run the unit, simulate a high reading as per the maker's method, and confirm the effluent is recirculated to the bilge tank and the alarm is recorded
- Explain the controls: the overboard valve is sealed and logged, the keys are held by the Chief Engineer, and the unit is run only with permission
- If the OWS is defective, explain that you stop overboard discharges, keep bilge water on board, record the failure in the ORB, report to the company and land residues ashore
- If tampering or a bypass pipe is found, explain that you do not use the system, preserve the evidence, report straight away to the Master and the company, and follow the company reporting channels
- Explain that any suspicion of illegal discharge through other engine room piping is reported in the same way, without fear of retaliation
What the inspector looks for
- A 15 ppm alarm calibration certificate within the maker's interval (no more than five years)
- Overboard valve closed, sealed and labelled as needing Chief Engineer or Master authority
- System flanges and connections sealed as per the approved drawing, with no signs of tampering or bypass
- Alarm and three-way valve or automatic stop tested, with records
- ORB Part I entries that agree with the OWS records
Have ready to show
- OWS type approval and 15 ppm alarm calibration certificate
- Seal log and approved seal drawing
- OWS and alarm test records in the PMS
- ORB Part I and the 15 ppm alarm data memory
- Maker's operation and maintenance manuals
- The company SMS procedure on oil filtering equipment
Avoid
- An expired calibration certificate
- Missing seals, flexible hoses or spool pieces that could act as a bypass
- No warning sign at the overboard valve
- OWS running hours that do not match the ORB discharges