6.6.2 Oil discharge monitoring and control system (ODME)
Rotational 1ChemicalOilAsked to: Master, Chief Officer, 2nd / 3rd Officer, Chief Engineer, Engineer officersWhere: Cargo Control Room, Main Deck, PumproomOnly if it applies to the ship
On oil and chemical tankers carrying oil, do the Master and officers know the company procedure for operating the oil discharge monitoring equipment, and is the ODME in good order and used in line with the procedure, the maker's manual and MARPOL Annex I?
In one lineFlush and test the ODME, discharge only within MARPOL limits, stop at once on alarm or sighted oil, keep records three years.
How to answer
- Describe the test run: flush with clean water, check zero, check the flow meter, alarms and overboard valve interlock, then start the discharge, as per the manual
- Explain the discharge criteria and that the slop tank interface is checked before and during decanting
- If the ODME fails, explain that you stop discharges, record the failure, report to the company and flag, and use manual operation only as the manual and flag allow (with manual input of flow and readings and constant visual watch). Otherwise keep the slops on board
- If oil is seen astern, explain that you stop the discharge at once, inform the Master, record the time and position, investigate, and report as required
- Make sure the oil type setting on the ODME matches the cargo, and know that some products cannot be measured by the ODME
What the inspector looks for
- A type-approved ODME and operations manual, with calibration and maintenance records
- ODME records and printouts kept for three years, matching ORB Part II entries
- Discharge limits understood: en route, outside special areas, more than 50 nm from land, instantaneous rate no more than 30 litres per nautical mile, and a total quantity limit
- Test run and flushing before use; the overboard valve interlocked with the ODME
- Actions on ODME failure and on sighting oil astern
Have ready to show
- ODME operation manual and type approval
- ODME printouts and records (three years)
- ORB Part II decanting entries
- ODME calibration and maintenance records
- Slop tank interface readings
Avoid
- ODME printouts missing or not matching the ORB
- Discharges outside the allowed criteria or areas
- Interlock bypassed, or no test run before discharge
- Officers unaware of the manual mode limitations
Practise in the interview trainer All questions