8.3.19 Indicators and alarms for the inert gas system
Rotational 2ChemicalOilAsked to: Master, Chief Officer, 2nd / 3rd Officer, Engineer officersWhere: Cargo Control Room, Engine Control RoomOnly if it applies to the ship
Can the Master and officers explain each IGS indicator and alarm, how it works and how it is tested, and have these been run, maintained and calibrated as the maker and the company require?
In one lineKnow every IGS alarm and set point, test and calibrate them per PMS, and switch to backup monitoring and restrict operations if one fails.
How to answer
- Explain each indicator and alarm and its set point.
- Describe how and when alarms are tested and show the records.
- Explain how instruments are calibrated or compared (pressure gauges against a test gauge, analyser with calibration gas).
- Describe failure actions: report to the Master, use portable instruments or local gauges for monitoring, restrict operations as the company procedure requires, and arrange repair.
- Show the recorder charts or electronic trends.
What the inspector looks for
- Indicators: oxygen content, IG main pressure, temperature, and their recorders in the CCR and other required positions
- Alarms: high oxygen, low/high IG pressure, high temperature, low scrubber water, deck seal level, blower or generator failure, power failure
- Alarm test records and set points
- Calibration of pressure transmitters and analysers
- Actions if an indicator or alarm fails
Have ready to show
- IGS alarm test records
- Alarm set point list
- Calibration records for analysers and pressure transmitters
- Recorder charts or IAS trends
- Defect reports
- Company SMS IGS procedure
Avoid
- Alarms not tested or found inoperative
- Recorder not working
- Indicator failures not reported
← 8.3.18 Inert gas system pressure/vacuum-breaking (P/V) device(s)8.3.20 Connections and interconnections to/with the inert gas system piping →
Practise in the interview trainer All questions