8.3.23 Cargo tank temperature monitoring systems

Rotational 2ChemicalOilAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Cargo Control Room, Main Deck

Do the Master and officers know the company procedures for maintaining, testing and calibrating cargo temperature monitoring equipment, and is it in good condition?

In one lineDemonstrate the system, compare fixed sensors with a calibrated portable UTI, record the results and report faulty sensors.

How to answer

  • Demonstrate the fixed temperature monitoring display and explain the alarm settings.
  • Explain how you check accuracy: compare with calibrated portable UTI readings at the same level and record differences.
  • Explain the calibration interval and who performs it.
  • Describe actions if a sensor is faulty: report, use portable readings, inform charterer if heating or limits are affected.
  • Show the comparison and calibration records.

What the inspector looks for

  • Fixed temperature sensors working in each tank, with alarms where fitted
  • Comparison with portable UTI readings and calibration records
  • Demonstration of the system and alarm settings
  • PMS entries and defect reports

Have ready to show

  • Temperature monitoring system display
  • Comparison records fixed vs portable
  • Calibration certificates
  • PMS entries
  • Defect reports

Avoid

  • Faulty sensors not reported
  • No comparison or calibration records
  • Officers unable to demonstrate the alarms