CoreChemicalOilAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Cargo Control Room, Main Deck
Do the Master and officers know how the company wants the cargo tank high-level alarms and the separate overfill (high-high) alarms maintained, tested and set, and are these alarms fully working at the correct settings?
In one lineAlarms tested before loading, set points known and recorded, never isolated without Master's authority and alternative monitoring.
How to answer
- State the set points and show where they are recorded.
- Explain how alarms are tested: test function or physical float/sensor test per the maker, before loading, with results logged.
- Explain that isolation is only allowed for defined cases such as testing or a confirmed defective sensor, with Master's authorisation, a defect report and alternative monitoring (e.g. frequent manual ullages).
- Describe what happens on alarm: stop loading into that tank, check the level, adjust the line-up.
- Show the defect record and repair plan if any alarm is out of order.
What the inspector looks for
- Alarm set points for each tank (typically around 95% high and 98% high-high, or as the company specifies)
- Testing before each loading or as per PMS, with records
- Independence of the overfill alarm from the gauging system where required
- Conditions under which alarms may be isolated, and authorisation
- Function test on deck (visual and audible) and in the CCR
Have ready to show
- High-level/overfill alarm test records
- Alarm set point list
- PMS maintenance history
- Override/isolation log with Master's authorisation
- Maker's manual for the alarm system
- Pre-loading checklist
Avoid
- Alarms not tested before loading
- Alarms isolated without authority or record
- Set points not known or inconsistent
← 8.3.3 Flue gas inert gas system8.3.5 Gauging and sampling static accumulator cargo in non-inerted tanks →