8.3.5 Gauging and sampling static accumulator cargo in non-inerted tanks
CoreChemicalOilAsked to: Master, Chief Officer, 2nd / 3rd Officer, RatingsWhere: Cargo Control Room, Interview - Deck Rating, Main DeckOnly if it applies to the ship
Do the Master, deck officers and ratings know and follow the company rules for gauging (dipping or ullaging) and sampling low-conductivity flammable cargoes that build up static, when the tanks are not inerted?
In one lineNon-inert tank with static accumulator: no conductive equipment during loading and for 30 minutes after, unless via sounding pipe; always bonded.
How to answer
- Explain what a static accumulator is (low conductivity, such as many clean products) and that charge builds up during loading and takes time to relax.
- State that conductive dipping, ullaging or sampling equipment is not introduced during loading and for 30 minutes after loading stops, except through a sounding pipe that reaches near the tank bottom.
- Explain that the equipment is bonded to the ship before it is opened to the tank and stays bonded until removed.
- Explain the use of natural fibre or approved cords, not synthetic rope, for lowering sample bottles.
- If you are a rating, show the bonding clip on the UTI tape and how you connect it.
What the inspector looks for
- Crew knowledge of what a static accumulator cargo is and why it is hazardous in a non-inert tank
- Waiting time after loading before introducing metallic or conductive equipment (ISGOTT recommends 30 minutes) unless done through a sounding pipe
- Bonding of equipment before it enters the tank
- No synthetic ropes or non-approved materials for lowering samplers
- Use of closed or restricted gauging where possible
Have ready to show
- Company SMS procedure for gauging/sampling static accumulators
- ISGOTT on board
- Portable UTI tape with bonding cable
- Sampling equipment and approved cord
- Cargo SDS showing conductivity/static accumulator status
- Toolbox talk record
Avoid
- Sampling or ullaging during loading without a sounding pipe
- Bonding cable missing or not connected
- Synthetic rope used for lowering equipment
← 8.3.4 Cargo tank high level and overfill alarms8.3.6 Loading static accumulator cargo into non-inerted tanks →
Practise in the interview trainer All questions