SeaVint

8.3.6 Loading static accumulator cargo into non-inerted tanks

CoreChemicalOilAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Cargo Control Room, Main DeckOnly if it applies to the ship

Do the Master and deck officers know and follow the company rules for loading low-conductivity flammable cargoes that build up static charge into tanks without an inert atmosphere?

In one lineStart slowly at about 1 m/s at the inlet until covered, avoid splash and water, then wait 30 minutes before gauging.

How to answer

  • Explain why the initial rate is limited: high velocity and splashing generate static charge in low-conductivity cargo.
  • State the restriction you apply: about 1 m/s at the tank inlet until the inlet is covered (per ISGOTT/company guidance), then the agreed maximum rate.
  • Explain that you avoid introducing air or water into the cargo, and that lines and tanks are drained of water beforehand.
  • Describe the 30-minute relaxation time before introducing conductive gauging/sampling equipment.
  • Show how the reduced rate is written into the loading plan and agreed with the terminal.

What the inspector looks for

  • Initial loading rate restriction until the tank inlet is well covered (ISGOTT recommends 1 m/s at the inlet)
  • Avoidance of splash filling, free water, and air or gas bubbling through the cargo
  • Relaxation time before gauging or sampling
  • Loading plan showing the reduced initial rate and maximum rate

Have ready to show

  • Loading plan with initial and maximum rates
  • Ship/shore safety checklist and agreed rates
  • Cargo SDS (conductivity)
  • Company SMS procedure for static accumulators
  • Cargo log showing rate changes

Avoid

  • Loading at full rate from the start into a non-inert tank
  • No reference to static accumulator precautions in the plan
  • Gauging during loading without precautions

Practise in the interview trainer All questions

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.