SeaVint

8.6.3 Cargo tank relief valves

Rotational 1LNGLPGAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Cargo Control Room, Main Deck

Do the Master and officers know the company procedures for inspecting, maintaining and testing the cargo tank relief valves and for changing their settings?

In one lineChange relief settings only with approval, reset alarms to match, log it, test per PMS, keep enough relief capacity if one valve is out.

How to answer

  • Explain the relief valves fitted (usually pilot-operated, at least two per tank) and their current set pressure.
  • Walk the inspector through changing the set pressure: Master's approval, change pilots or settings as per the manual, adjust the high-pressure alarm to match, record in the cargo log.
  • Explain inspection and testing: routine checks of pilot sensing lines and drains, bench testing and overhaul at the intervals in the PMS/class rules.
  • Describe malfunction actions: control tank pressure by reliquefaction or other means, isolate the faulty valve only as the manual permits so the required relief capacity remains, report to the company.
  • If an automated venting system is fitted, explain its set points and how it is tested.

What the inspector looks for

  • Procedure for changing between alternative set pressures (e.g. harbour/high-pressure setting) and matching tank pressure alarms
  • Records of set pressure changes in the cargo log
  • Overhaul and bench test records with set pressures per PMS and class
  • Actions on a malfunctioning relief valve, including isolation rules in the Cargo System Operation Manual
  • Operation of any automatic tank venting/pressure control system

Have ready to show

  • Relief valve set pressure change log
  • Relief valve test/overhaul certificates
  • Cargo System Operation Manual section on relief valves
  • Tank pressure alarm set point list
  • PMS records
  • Certificate of Fitness (MARVS)

Avoid

  • Set pressure changed without matching alarm settings
  • No record of setting changes
  • Relief valve isolated outside the manual's limits

Practise in the interview trainer All questions

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.