SeaVint

8.6.2 Cargo transfer Emergency Shut Down (ESD)

CoreLNGLPGAsked to: Master, Chief Officer, 2nd / 3rd Officer, RatingsWhere: Bridge, Cargo Control Room, Cargo Manifold, Interview - Deck Rating, Main Deck

Do the Master, officers and ratings who take part in cargo work understand how the cargo transfer ESD system works, and is the equipment kept working, inspected, tested and maintained at regular intervals?

In one lineESD closes valves and stops pumps; valves close within 30 seconds; test with shore before transfer; inhibit only on Master's written authority.

How to answer

  • Explain what the ESD system shuts down and what automatically triggers it (e.g. tank high-high level, fire detection/fusible links, loss of control power, signal from shore).
  • Point out the manual activation points around the deck and CCR.
  • State the measured closing times of the manifold ESD valves and explain how the agreed loading rate is checked against them to avoid pressure surge.
  • Describe the pre-transfer ESD test with the terminal, normally done warm before cargo arrives and recorded on the checklist.
  • Explain that ESD may be inhibited only for testing or a defined operation under the Master's written authority, with the inhibit logged and removed afterwards.

What the inspector looks for

  • Whether crew can name what an ESD trip does: closes ESD valves, stops cargo pumps and compressors, and signals the terminal through the ship/shore link
  • Locations of manual ESD push-buttons and fusible links (manifolds, tank domes, CCR, bridge, compressor room as fitted)
  • ESD valve closing times measured and recorded; the IGC Code requires closure within 30 seconds, and loading rate must suit the closing time to limit surge
  • Ship/shore ESD link type (fibre-optic, electric or pneumatic) and pre-transfer warm/cold tests
  • Control of ESD inhibits: who may authorise them and how they are logged

Have ready to show

  • ESD test records and pre-transfer test checklist
  • ESD valve closing time records
  • ESD cause-and-effect matrix in the Cargo System Operation Manual
  • Ship/shore link connectors and test record
  • Inhibit/override log
  • PMS records for ESD valves and actuators

Avoid

  • Crew unable to locate ESD push-buttons
  • Closing times not measured or longer than allowed
  • ESD inhibited without Master's authority or record
  • Ship/shore link not tested before transfer

Practise in the interview trainer All questions