SeaVint

8.6.1 Cargo tank overfill alarms

CoreLNGLPGAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Cargo Control Room, Main Deck

Do the Master and officers know the company procedures for maintaining, testing and setting the independent high-level and overfill alarms of gas carrier cargo tanks, and are these alarms working and properly set?

In one lineIndependent alarms tested before loading, set to filling limits, overrides only with Master's permission and logged.

How to answer

  • State the set points and show how they relate to the filling limits.
  • Explain how alarms are tested before loading and recorded.
  • Explain that overrides are only for specific cases such as testing, with Master's permission, and recorded.
  • Describe actions on alarm: stop loading, check levels, investigate.

What the inspector looks for

  • Alarm set points in line with the filling limits
  • Independence from the primary gauging system
  • Overfill sensor linked to the ESD system
  • Test records and when overrides are allowed

Have ready to show

  • Alarm test records
  • Set point list
  • Override log
  • Cargo system operation manual
  • PMS records

Avoid

  • Alarms not tested
  • Overrides without permission
  • Set points not aligned with filling limits

Practise in the interview trainer All questions

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.