Air gauge 0.2 bar above normal / relief valve blowing
Hamworthy Super Trident ST6A, 生化污水处理装置,imo mepc.2(vi)
可能原因
Clogged diffuser elements or dirty filters
处理方法
制造商说明书,第 59 页Replace diffuser elements and clean filter cartridges
Hamworthy Super Trident ST6A 的其他故障
Tank overflow / high level alarmDischarge pump failure, pipe blockage or excessive inflow (leaking WC flush valves)Bad smell from the unitAnaerobic tank: compressor, air-lifts or diffusers not working, or too much sludgePoor effluent qualityLack of oxygen, killed bacteria by disinfectant cleaners, sludge not returning, too much flushing waterScum on the settling tankSkimmer or air-lifts not workingFoaming in the aeration tank and ventToo much cleaning agentDischarge pump gives no flowClosed valves, blocked suction, air leaks or loops in suction pipeReduced or irregular pump dischargeChoked impeller, valve or non-return valve partly closed
依据制造商说明书《Sewage treatment plant manual》。作业前请核对船上的原件。