JOWA REP-1L
饮用水紫外线消毒器
JOWA REP-1L sterilises drinking water with one low-pressure UV lamp in a stainless steel chamber. A photocell measures UV intensity and gives an alarm and closes the outlet solenoid valve when it falls below 30 %; a lamp ammeter monitors the lamp. It is fitted after the pH filter, storage tank and hydrophore, as close to the tapping point as possible. The manual covers specification, installation, start-up, chamber cleaning, lamp and quartz jacket replacement, a troubleshooting chart, wiring and parts.
保养规程
Replacing a quartz jacket
- Switch off the operating switch and the automatic fuse; drain the chamber. 第 14 页
- Remove the wing nuts and end covers, disconnect the lamp and pull it out. 第 14 页
- Remove the O-ring flange (three 6 mm socket screws), slide the quartz out on a 10–18 mm wooden or plastic rod. 第 14 页
- Fit new O-rings (soap inside), wipe the quartz with alcohol and do not touch it with bare hands. 第 14 页
- Slide the new quartz in on the rod, refit flanges hand-tight to bottom, pressurise and check for leaks; refit lamp and covers. 第 14 页
故障及处理方法
Low reading on lamp meterLamp burnt out, bad connections, ballast fault, wrong supply voltageLow reading on intensity meterLamp faulty, dirty chamber, photocell or circuit board faultyBoth meters read zeroLamp faulty or automatic fuse offSolenoid valve does not openLamp fault, intensity alarm, alarm relay faulty
技术参数
| UV lamp | 1 low-pressure lamp, 158 cm, 65 W (27 W at 253.7 nm) | 第 3 页 |
|---|---|---|
| UV dose | > 35 000 µWs/cm² at 2.7 m³/h, 60 % transmission | 第 3 页 |
| Capacity | 2.7–5.4 m³/h depending on water quality | 第 3 页 |
| Intensity alarm | below 30 % | 第 3 页 |
| Power | 150 W, 230 V 50/60 Hz | 第 3 页 |
| Working pressure | up to 10 bar | 第 3 页 |
| Chamber | SS 316, 1630 × 104 × 275 mm, 16 kg | 第 3 页 |
| Lamp voltage (unlit) | about 600 V for 152 cm lamp | 第 16 页 |
来源:制造商说明书《EM-26 RE-UV-PURIFIERS》,共 21 页。页码以原文为准。作业前请核对船上的说明书。