ERR 10 — sensor cleaning required
JOWA SEAGUARD, 15 ppm 舱底水报警器(ows 监测仪)
可能原因
No clean water, dirty sensor, failed auto-flush, air bubbles, faulty sensor
处理方法
制造商说明书,第 22 页Check the clean water supply, clean the sensor and repeat the flush, check the water, replace the sensor
JOWA SEAGUARD 的其他故障
ERR 2 — clock failureHardware failureERR 4 — memory errorMemory card loose or faulty (corroded contacts)ERR 8 — sensor not connectedBroken/loose cable or faulty sensorERR 20 — sensor temperatureTemperature outside +1…+60 °C or faulty sensorERR 40 — log truncatedLog recording interrupted by power failureERR 80 — unknown errorSoftware failure or no ID in the Information menuPPM: O/R — out of rangeValue outside 0–30 ppm, sample too dirty, faulty sensor
依据制造商说明书《Manual JOWA SEAGUARD》。作业前请核对船上的原件。