Westfalia VESC-1

Separator control unit

The Westfalia VESC-1 control unit runs the separation, sludge discharge (partial and total ejection) and displacement programs of a self-cleaning separator and monitors it. Inputs include motor fault, clean-oil outlet pressure switch, feed temperature min/max switches, feed pump control and sludge tank level switches; outputs drive the feed, displacement/filling water and operating water valves, the sludge pump, a collective alarm and a klaxon. The manual and parts list explains the inputs and outputs, programming of times, operation (start, separation stop, separator off), monitoring and alarms, short-circuit and internal fault finding, and the watchdog.

Click a part on the model to see its number and purpose.Open the 3D manual

Maintenance procedures

Stopping separation

  1. Press key 0 in separation mode: the unit runs waiting, displacement, waiting after displacement and speed recovery, then ejects with minimum product loss. p. 37
  2. Pressing 0 during ejection interrupts the program at once. p. 37
  3. If the motor starter is switched off with the feed valve open, a total ejection is made automatically. p. 37

Clearing an alarm

  1. Read the fault text on the display (e.g. clean oil outlet, feed temperature). p. 37
  2. Eliminate the cause, press Enter to acknowledge, then press I to restart separation. p. 37

Faults and what to do

Technical specifications

Clean oil outlet pressure alarm delayabout 15 s, then feed valve closesp. 37
Feed temperature alarm delayabout 15 sp. 37
Feed pump post-running20 minutes after stop signalp. 16
Sludge tank level switch delay5 sp. 16
Collective alarm contactclosed = normal, open = faultp. 18

Source: manufacturer's manual “EM-21-3 WESTFALIA CONTROL UNIT MODEL VESC-1”, 80 pages. Page numbers refer to the original. Check against the manual on board before work.