Westfalia VESC-1
Unit kontrol separator
The Westfalia VESC-1 control unit runs the separation, sludge discharge (partial and total ejection) and displacement programs of a self-cleaning separator and monitors it. Inputs include motor fault, clean-oil outlet pressure switch, feed temperature min/max switches, feed pump control and sludge tank level switches; outputs drive the feed, displacement/filling water and operating water valves, the sludge pump, a collective alarm and a klaxon. The manual and parts list explains the inputs and outputs, programming of times, operation (start, separation stop, separator off), monitoring and alarms, short-circuit and internal fault finding, and the watchdog.
Prosedur perawatan
Stopping separation
- Press key 0 in separation mode: the unit runs waiting, displacement, waiting after displacement and speed recovery, then ejects with minimum product loss. hlm. 37
- Pressing 0 during ejection interrupts the program at once. hlm. 37
- If the motor starter is switched off with the feed valve open, a total ejection is made automatically. hlm. 37
Clearing an alarm
- Read the fault text on the display (e.g. clean oil outlet, feed temperature). hlm. 37
- Eliminate the cause, press Enter to acknowledge, then press I to restart separation. hlm. 37
Gangguan dan cara mengatasinya
Spesifikasi teknis
| Clean oil outlet pressure alarm delay | about 15 s, then feed valve closes | hlm. 37 |
|---|---|---|
| Feed temperature alarm delay | about 15 s | hlm. 37 |
| Feed pump post-running | 20 minutes after stop signal | hlm. 16 |
| Sludge tank level switch delay | 5 s | hlm. 16 |
| Collective alarm contact | closed = normal, open = fault | hlm. 18 |
Sumber: manual produsen “EM-21-3 WESTFALIA CONTROL UNIT MODEL VESC-1”, 80 halaman. Nomor halaman mengacu ke dokumen asli. Periksa manual di kapal sebelum bekerja.